UNITREX (Universal Trace Residue Extractor) is a compact micro processor controlled instrument to facilitate the extraction and concentration of pesticide residues from fats and oils.

Wishlist
Product description
The unit consists of a cylindrical aluminium block containing a cartridge heater, standing on top of a control base which incorporates both the heater controls and the pneumatics for the purge gas system. The block provides ten stations for simultaneous running of up to nine samples and one fortified sample.
The temperature of the unit is sensed by means of a chromel- alumel thermocouple mounted in the base of the heater block. The temperature is controlled to +/- 1oC by means of a micro processor temperature controller built into the lower control section of the instrument. Purge gas (nitrogen) enters from the rear of the instrument and is controlled by a pressure regulator from the front panel. The pressure is displayed by a micro processor controlled digitalpressure meter also built into the lower control section of the instrument. The purge gas is distributed by a ten
port manifold which supplies gas to each station through calibrated restrictors built into the manifold unions. The flow through these restrictors has been carefully balanced to ensure that each sample is subjected to similar purge gas flows. The head pressure on the manifold is indicated by the digital pressure reading on the control panel of the instrument.
The purge gas is led into the fractionation tube through a septum head assembly which is attached to the glass tube by means of a union that utilizes a graphite ferrule. The sample is
injected through the septum into of the fractionation tube. The fractionation tube, which is of all glass construction, is designed so that the sample passes down a central tube then out and up into the annular space between the outer face of the central tube and the inner wall of the fractionation tube. In doing this, the sample is spread over the glass surfaces as a thin film; the pesticides are then partitioned into the gas stream and are carried up and out of the side arm of
the fractionation tube and into a trap packed with Sodium Sulphate and partially deactivated Florisil*. After the appropriate period of time has elapsed, the trap is removed and connected to a reservoir into which mixed solvent is added. The solvent elutes the pesticides and leaves behind the fat volatiles.